LabMaster 916SZi-A
16 GHz, 40 GS/s, 4ch, 20 Mpts/Ch LabMaster Slave Acquisition Unit
LabMaster 913SZi-A
13 GHz, 40 GS/s, 4ch, 20 Mpts/Ch LabMaster Slave Acquisition Module. 50 Ohm Inputs
LabMaster 916SZi-A
16 GHz, 40 GS/s, 4ch, 20 Mpts/Ch LabMaster Slave Acquisition Module. 50 Ohm inputs.
LabMaster 920SZi-A
20 GHz, 40 GS/s, 4ch, 20 Mpts/Ch LabMaster Slave Acquisition Module. 50 Ohm inputs.
LabMaster 930SZi-A
30 GHz, 80 GS/s, 40 Mpts/Ch Digital Bandwidth Interleaved (DBI) Slave Acquisition Module, 50 ohm Inputs. Also operates in 20 GHz, 40 GS/s, 4ch, 20 Mpts/Ch mode
LabMaster 10-20Zi-A
20 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-25Zi-A
25 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-30Zi-A
30 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-36Zi-A
36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Slave Acquisition Module, 50 Ohm Input
LabMaster 10-50Zi-A
50 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.
LabMaster 10-59Zi-A
59 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.
LabMaster 10-65Zi-A
65 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode.
LabMaster 10-100Zi-A
100 GHz, 240 GS/s, 96 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode. or, 65 GHz, 160 GS/s, 1ch, 64 Mpts/Ch w/ 2 ch at 36 GHz
Vertical System |
|
Bandwidth | 16 GHz |
Analog Bandwidth (Max) | 16 GHz |
Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) |
16 GHz (≥10 mV/div) |
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) |
For 9xxMZi-A "Master" Acquisition Module: 3.5 GHz (≥10 mV/div) For MCM-Zi Master Control Module: Not Applicable |
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) |
For 9xxMZi-A "Master" Acquisition Module: 500 MHz (typical, ≥2 mV/div) For MCM-Zi Master Control Module: Not Applicable |
Rise Time (10-90%, 50 Ω) |
28.5 ps (test limit, flatness mode) |
Rise Time (20-80%, 50 Ω) |
21.5 ps (flatness mode) |
Input Channels | Up to 80 |
Input Channels |
Up to 80, depending on configuration selected. (Any combination of up to 80 ProLink input channels, or 4 ProBus input channels) |
Bandwidth Limiters | 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz, 13 GHz |
Input Impedance |
ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe |
Input Coupling |
ProLink Inputs - 50 Ω: DC, GND ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND |
Maximum Input Voltage |
50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div 50 Ω (ProBus): ±5 Vmax, 3.5 Vrms 1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC) |
Channel-Channel Isolation |
DC to 10 GHz: 50 dB (>315:1) 10 to 15 GHz: 46 dB (>200:1) 15 to 20 GHz: 40 dB (>100:1) (For any two ProLink input channels, same or different v/div settings, typical) |
Vertical Resolution | 8-bits |
Vertical Resolution | 8 bits; up to 11 bits with enhanced resolution (ERES) |
Sensitivity |
50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom) 50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable |
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) | ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V |
Vertical Noise Floor (50 mV/div) | 1.90 mVrms (typical) |
Offset Range |
50 Ω (ProLink): ±500 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 50 Ω (ProBus): ±750 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 1 MΩ: ±1V @ 2-140 mV/div ±10V @ 142mV-1.40V/div ±100V @ 1.42V-10V/div |
DC Vertical Offset Accuracy | ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit) |
Horizontal System |
|
Timebases | Internal timebase with 10 GHz clock frequency common to all input channels. Single, distributed 10 GHz clock for all channels ensures precise synchronization with timing accuracy between all channels identical to that provided within a single, conventional oscilloscope package. |
Time/Division Range | 20 ps/div-64 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div, user selectable at ≤10ns/div; Roll mode: Not available |
Clock Accuracy | < 1 ppm + (aging of 0.5ppm/yr from last calibration) |
Sample Clock Jitter |
up to 10µs Acquired Time Range: 100fsrms (Internal Timebase Reference) up to 6.4ms Acquired Time Range: 150fsrms (Internal Timebase Reference) |
Delta Time Measurement Accuracy | √2*√((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) (RMS)+(clock accuracy*reading)(seconds) |
Jitter Measurement Floor | √((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) secondsrms (TIE) |
Jitter Between Channels |
<300fsrms (TIE, typical, measured at maximum bandwidth) |
Trigger and Interpolator Jitter | <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware), |
Channel-Channel Deskew Range | ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel |
External Timebase Reference (Input) | 10 MHz; 50 Ω impedance, applied at the rear input of 9xxMZi-A Master Acquisition Module or MCM-Zi Master Control Module |
External Timebase Reference (Output) | 10 MHz; 50 Ω impedance, output at the rear of 9xxMZi-A Master Acquisition Module or MCM-Zi Master Control Module |
Acquisition System |
|
Sample Rate |
40 GS/s (80 GS/s with optional interleaving) |
Single-Shot Sample Rate/Ch |
40 GS/s on each channel. (80 GS/s when combining channels using the optional WM8Zi-2X80GS External Interleaving Device) |
Random Interleaved Sampling (RIS) | 200 GS/s for repetitive signals (20 ps/div to 10 ns/div) |
Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
Intersegment Time | 1 µs |
Maximum Acquisition Memory | 256 Mpts/Ch |
Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments) |
20 M / 20 M / 20M Memory and Sample Rate can be doubled in half channel mode with use of WM8Zi-2X80GS External Interleaving Device. (2000) |
Memory Options (4 Ch / 2 Ch / 1Ch) (Number of Segments) |
S-32 Option: 32M / 32M / 32M (7,500) M-64 Option: 64M / 64M / 64M (15,000) L-128 Option: 128M / 128M / 128M (15,000) VL-256 Option: 256M / 256M / 256M (15,000) Note: On all memory options, memory and sample Rate can be doubled in half channel mode with use of WM8Zi-2X80GS External Interleaving Device. |
Acquisition Processing |
|
Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution |
Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
Interpolation | Linear or Sin x/x |
Triggering System |
|
Coupling Mode | DC, AC, HFRej, LFRej |
Hold-off by Time or Events | From 2 ns up to 20 s or from 1 to 99,999,999 events |
Internal Trigger Range | ±4.1 div from center |
External Trigger Sensitivity, (Edge Trigger) |
For 9xxMZi-A "Master" Acquisition Module only: 2 div @ < 1 GHz, 1.5 div @ < 500 MHz, 1.0 div @ < 200 MHz, (for DC coupling) |
External Trigger Input Range | For 9xxMZi-A "Master" Acquisition Module only: Aux (±0.4 V); Aux/10 (±4 V) |
Modes | Normal, Auto, Single, and Stop |
Sources |
Using 9xxMZi-A Master Acquisition Module: Any Ch 1-4 (Edge, Window, TV, SMART, Cascade triggers), AUX or AUX/10, or internal Fast Edge on 9xxMZi-A; any input channel (Edge trigger only) on 9xxSZi-A Acquisition Modules (Channels 5 and higher). Using MCM-Zi Master Control Module: Any Ch 1-4 of the first 9xxSZi-A Acquisition Module input (Edge, Window, TV, SMART, Cascade triggers), or internal Fast Edge on the MCM-Zi module; any input channel (Edge trigger only) on additional 9xxSZi-A Acquisition Modules (Channels 5 and higher). Slope and level unique to each source except line trigger. |
Pre-trigger Delay | 0-100% of memory size (adjustable in 1% increments of 100 ns) |
Post-trigger Delay | 0-10,000 divisions in real time mode, limited at slower time/div settings |
Trigger Sensitivity with Edge Trigger ProLink Inputs |
For 9xxMZi-A "Master" Acquisition Module or Ch 1-4 of a 9xxSZi-A "Slave" Acquisition Module when used with a MCM-Zi Master Control Module: 3 div @ < 15 GHz, 1.5 div @ < 3 GHz, 1.0 div @ < 200 MHz, (for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω ) |
Trigger Sensitivity with Edge Trigger ProBus Inputs |
For 9xxMZi-A "Master" Acquisition Module or Ch 1-4 of a 9xxSZi-A "Slave" Acquisition Module when used with a MCM-ZI Master Control Module: 2 div @ < 3.5 GHz, 1.5 div @ < 1.75 GHz, 1.0 div @ < 200 MHz, (for DC coupling, ≥ 10 mV/div, 50 Ω ) |
Max. Trigger Frequency, SMART Trigger |
For 9xxMZi-A "Master" Acquisition Module or Ch 1-4 only of a 9xxSZi-A "Slave" Acquisition Module when used with an MCM-Zi Master Control Module: 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) |
Basic Triggers |
|
Edge | Triggers when signal meets slope (positive, negative, or either) and level condition. |
Window | Triggers when signal exits a window defined by adjustable thresholds |
TV-Composite Video | Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative). |
SMART Triggers |
|
State or Edge Qualified | Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events. |
Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. |
Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. |
Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern. |
SMART Triggers with Exclusion Technology |
|
Glitch | Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults. |
Width (Signal or Pattern) | Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults. |
Interval (Signal or Pattern) | Triggers on intervals selectable between 1 ns and 20 s. |
Timeout (State/Edge Qualified) |
Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events. |
Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. |
Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. |
Exclusion Triggering | Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met |
Cascade (Sequence) Triggering |
|
Capability | Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event. |
Types |
Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only. Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only. Cascade A then B then C: Edge, Window, Pattern (Logic) |
Holdoff |
Holdoff between A and B or B and C is selectable by time (1ns to 20s) or number of events. Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage. |
High Speed Serial Protocol Triggering |
|
Data Rates |
Available only with 9xxMZi-A Master Acquisition Module Option LM9Zi-6GBIT-80B-8B10B-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only Option LM9Zi-14GBIT-80B-8B10B-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only |
Pattern Length | 80 bits NRZ, eight 8b/10b symbols |
Clock and Data Outputs | No Clock and Data Recovery outputs provided |
Low Speed Serial Protocol Triggering (Optional) |
|
Optionally available | Using 9xxMZi-A Master Acquisition Module: I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, I2S (Audio), MIL-1553 |
Measurement Trigger |
|
Measurement Trigger Capability | Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger. |
Color Waveform Display |
|
Type | On 9xxMZi-A "Master" Acquisition Module or 9CZi-A Master Control Module: Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen |
Resolution | WXGA; 1280 x 768 pixels. |
Number of traces | Display a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces. |
Grid Styles | Auto, Single, Dual, Triple, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Twelve, Sixteen. Up to twenty grids available with some software options. |
Waveform Representation | Sample dots joined, or sample dots only |
Integrated Second Display |
|
Type |
Supports touch screen integration of user-supplied second display with split-grid capability. (Note: touch screen driver for second display may not be a Fujitsu driver) For 9xxMZi-A Master Acquisition Module - requires ordering of option LM9Zi-VIDEOCARD-Zi-EXTDISP-15 to relace the standard video card in the LabMaster CPU, so performance described in "External Monitor Port" is no longer provided. MCM-Zi Master Control Module provides all video outputs required, and supports extended desktop operation. |
Resolution | Determined by display chosen by user |
LeCroy WaveStream™ Fast Viewing Mode |
|
Operation | Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF |
Intensity | 256 Intensity Levels, 1-100% adjustable via front panel control |
Types | Select analog or color-graded |
Number of Channels | up to 80 simultaneously |
Max Sampling Rate | 40 GS/s (80 GS/s with optional WM8Zi-2X80GS external interleaving device) |
Persistence Aging | Select from 500 ms to Infinity |
Waveforms/second (continuous) | up to 2500 Waveforms/second |
Analog Persistence Display |
|
Analog and Color-Graded Persistence | Variable saturation levels; stores each trace's persistence data in memory |
Persistence Types | Select analog, color, or three-dimensional |
Trace Selection | Activate persistence on all or any combination of traces |
Persistence Aging | Select from 500 ms to infinity |
Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted |
High Speed Digitizer Output (Option) |
|
Type | Option LSIB-2. Installs in LabMaster 9xxMZi-A CPU or LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a 9xxSZi-A Module. |
Transfer Rate | up to 325 MB/s (typical) - Maximum of 4 channels (consult Teledyne LeCroy for >4 channels) |
Output Protocol | PCI Express, Gen 1 (4 lanes utilized for data transfer) |
Control Protocol | TCP/IP |
Command Set | Via Windows Automation, or via LeCroy Remote Command Set |
Zoom Expansion Traces |
|
Zoom Expansion Traces | Display up to 12 Zoom and 12 Math/Zoom traces |
Internal Waveform Memory |
|
Internal Waveform Memory | 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity. |
Setup Storage |
|
Front Panel and Instrument Status | Store to the internal hard drive, over the network, or to a USB-connected peripheral device. |
Interface |
|
Remote Control | Via Windows Automation, or via LeCroy Remote Command Set |
Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant |
GPIB Port | Supports IEEE - 488.2. Installs in LabMaster 9xxMZi-A CPU or MCM-Zi Master Control Module and uses one available PCIe slot normally used by a 9xxSZi-A Module. |
LSIB Port (optional) | Supports PCIe Gen1 x4 protocol with LeCroy supplied API. Installs in LabMaster 9xxMZi-A CPU or MCM-Zi Master Control Module and uses one available PCIe slot normally used by a 9xxSZi-A Module. |
Ethernet Port | Supports 10/100/1000BaseT Ethernet interface (RJ45 port) |
USB Ports |
9xxMZi-A CPU or MCM-Zi Master Control Module: minimum 2 total USB 2.0 ports on rear of unit to support Windows compatible devices 9xxMZi "Master" Acquisition Module or MCM-Zi Master Control Module: minimum 3 total USB 2.0 ports on front of unit to support Windows compatible devices |
External Monitor Port |
In 9xxMZi-A CPU: Dual Link DVI compatible to support internal display on 9xxMZi-A Master Acquisition Module (1280 x 768 pixel resolution) or customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution. Add LM9Zi-VIDEOCARD-EXTDESKTOP replacement videocard to support two DVI-D monitors with extended desktop (max 1920 x 1200 pixel resolution for both monitors). In MCM-Zi Master Control Module: Dual Link DVI compatible to support internal display on MCM-Zi Master Control Module (1280 x 768 pixel resolution) and customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution using extended desktop mode. |
Automatic Setup |
|
Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals |
Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range |
General |
|
Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. |
Processor/CPU |
|
Type | In 9xxMZi-A CPU or MCM-Zi Master Control Module: Intel® XeonTM X5660 2.8 GHz (or better). There are two processors in each CPU, and each processor has 6 cores for a total of 12 cores and an effective processor speed of 33.6 GHz. |
Processor Memory | 24 GB standard. Up to 192 GB optionally available. |
Operating System | Microsoft Windows® 7 Professional Edition (64-bit) |
Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. |
Environmental and Safety |
|
Temperature (Operating) | +5 °C to +40 °C |
Temperature (Non-Operating) | -20 °C to +60 °C |
Humidity (Operating) |
5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. |
Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude (Operating) | Up to 10,000 ft. (3048 m) at or below +25 °C |
Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) |
Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
Physical Dimensions |
|
Dimensions (HWD) |
9xxMZi-A "Master" Acquisition Module14"H x 18.4"W x 16"D (355 x 467 x 406 mm). 9xxMZi-A CPU - 5.7"H x 18.2"W x 20.8"D (145mm x 462mm x 527mm). 9xxSZi-A "Slave" Acquisition Module - 7"H x 18.2"W x 20.8"D (177mm x 462mm x 527mm). MCM-Zi Master Control Module - 10.9"H x 18.2"W x 15.6"D (277 x 462 x 396 mm) |
Weight |
9xxMZi-A "Master" Acquisition Module - 48 lbs. (22 kg) 9xxMZi-A CPU - 29 lbs. (13 kg) 9xxSZi-A "Slave" Acquisition Module - 37 lbs. (17 kg) MCM-Zi Master Control Module - 47 lbs. (21.4 kg) |
Shipping Weight |
9xxMZi-A "Master" Acquisition Module - 70 lbs. (32 kg) 9xxMZi-A CPU - 36 lbs. (16 kg) 9xxSZi-A "Slave" Acquisition Module - 44 lbs. (20 kg) MCM-Zi Master Control Module - 56 lbs. (25.5 kg) |
Auxiliary Input |
|
Signal Types | For External Trigger Input. Located in 9xxMZi-A "Master" Acquisition Module or Slave Acquisition Module #1 (rear-mounted BNC, 50 Ω) used with MCM-Zi Master Control Module. |
Coupling |
Using 9xxMZi-A Master Acquisition Module: 50 Ω: DC; 1 MΩ: AC, DC, GND Using MCM-Zi Master Control Module: 50 Ω only |
Max. Input Voltage | 5 Vrms (50 Ω); 250 V (Peak AC < 10 kHz + DC) (1 MΩ) |
Auxiliary Output |
|
Signal Types |
9xxMZi-A "Master" Acquisition Module: Select from calibrator, control signals or Off (Not available with MCM-Zi Master Control Module) |
Output Signal | 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ) |
Control Signals | Trigger enabled, trigger out, pass/fail status, off |
Connector Type | BNC, located on front of 9xxMZi-A "Master" Acquisition Module |
Probes |
|
Probes |
9xxMZi-A Models: Acquisition Module: Qty. (4) ÷10 Passive Probes 9xxSZi-A and MCM-Zi Models: No passive probes supplied |
Probe System |
9xxMZi-A "Master" Acquisition Module: Probus and ProLink. 9xxSZi-A "Slave" Acquisition Module: ProLink. Automatically detects and supports a variety of compatible probes. |
Scale Factors | Automatically or manually selected depending on probe used |
Calibration Output |
9xxMZi-A "Master" Acquisition Module: 1kHz square wave, 1Vp-p (typical), output to probe hook. 9xxMZi-A "Master" Acquisition Module and MCM-Zi Master Control Module: Fast Edge output, 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled |
Power Requirements |
|
Voltage |
LabMaster 9xxMZi-A "Master" Acquisition Module and 9xxSZi-A: 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II LabMaster 9xxMZi-A CPU: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II LabMaster MCM-Zi Master Control Module: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II |
Max. Power Consumption |
9xxMZi-A "Master" Acquisition Module - 850 W / 850 VA. 9xxMZi-A CPU - 400 W / 400 VA. 9xxSZi-A "Slave" Acquisition Module - 700 W / 700 VA. MCM-Zi Master Control Module - 450 W / 450 VA. Each Module and the CPU has a separate power cord. |
Certifications |
|
Certifications | CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12 |
Warranty and Service |
|
Warranty and Service |
3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services. |